Wholesale Dealers of One Step Real Time Pcr - Fungal fluorescence staining solution – Liming Bio

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our corporation insists all along the quality policy of "product top quality is base of organization survival; purchaser pleasure will be the staring point and ending of an company; persistent improvement is eternal pursuit of staff" plus the consistent purpose of "reputation very first, purchaser first" for Covid -19 Rapid Test, Salmonella Typhi (S. Typhi), Infection Neisseria Gonorrhoeae, We cordially welcome customers from at home and abroad to join us and cooperate with us to enjoy a better future.
Wholesale Dealers of One Step Real Time Pcr - Fungal fluorescence staining solution – Liming Bio Detail:

NTENDED USE
The FungusClearTM Fungal fluorescence staining solution is used for the rapid Identification of various fungal infections in human fresh or frozen clinical specimens, paraffin or glycol methacrylate embedded tissues. Typical specimens include scraping, nail and hair of dermatophytosis such as tinea cruris, tinea manus and pedis, tinea unguium, tinea capitis, tinea versicolor. Also include sputum, bronchoalveolar lavage(BAL), bronchial wash, and tissue biopsies from invasive fungal infection patients.

INTRODUCTION
Fungi are eukaryotic organisms. Beta-linked polysaccharides are found in fungi cell walls of various organisms such as chitin and cellulose. Various fungal and yeast types will stain fluorescently including Microsporum sp., Epidermophyton sp., Trichophuton sp., Candidia sp., Histoplasma sp. and Aspergillus sp. among others. The kit will also stain Pneumocystis carinii cysts, parasites such as Plasmodium sp., and regions of fungal hyphae undergoing differentiation. Keratin, collagen, and elastin fibers are also stained and may provide structural guidelines for diagnosis.

PRINCIPLE
Calcofluor White Stain is a non-specific fluorochrome that binds with cellulose and chitin contained in the cell walls of fungi and other organisms.
Evans blue present in the stain act as a counterstain and diminishes background fluorescence of tissues and cells when using blue light excitation.
10% potassium hydroxide are include in the solution for better visualization of fungal elements.
A range of 320 to 340 nm can be taken for emission wave lenght and the excitation occurs around 355nm.
Fungal or parasitic organisms appear fluorescent bright green to blue, while other material is reddish-orange fluorescent. Non-specific reactions may occur when tissues samples are used. May a yellowish-green background fluorescence is observed with such specimens but fungal and parasitic structures appears with much more intense. As well amebic cysts are fluorescent but trophozites will not stain or fluoresce.

STORAGE  AND  STABILITY
• The kit should be stored at 2-30°C until the expiry date printed on the label and protected from light.
• The valid date is 2 years.
• Do not freeze.
• Cares should be taken to protect components in this kit from contamination.Do not use if there is evidence of microbial contamination or precipitation.Biological contamination of dispensing equipments, containers or reagents can lead to false results.

Quick Details

Place of Origin:

Jiangsu, China

Brand Name:

FungusClear

Warranty:

Lifetime

After-sale Service:

Online Technical Support

Instrument classification:

class III

Pattern:

solution

Applied Location:

lab, hospital, clinic, pharmacy

Operation:

user-friendly

Benefits:

high accuracy/high detection rate

Type:

Pathological Analysis Equipments

Supply Ability:

5000 Box/Boxes per Month

Packaging & Delivery

Packaging Details

20 tests/box

Port

shanghai


Instructions


Product detail pictures:

Wholesale Dealers of One Step Real Time Pcr - Fungal fluorescence staining solution – Liming Bio detail pictures

Wholesale Dealers of One Step Real Time Pcr - Fungal fluorescence staining solution – Liming Bio detail pictures


Related Product Guide:

We have been ready to share our knowledge of internet marketing worldwide and recommend you suitable merchandise at most aggressive rates. So Profi Tools present you very best price of money and we are ready to develop alongside one another with Wholesale Dealers of One Step Real Time Pcr - Fungal fluorescence staining solution – Liming Bio , The product will supply to all over the world, such as: Denver, Bangladesh, Latvia, The best and original quality for spare parts is a most important factor for transportation. We may stick on supplying original and good quality parts even a little profit earned. God will bless us to do kindness business forever.
  • Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.
    5 Stars By Jenny from Montpellier - 2018.06.18 19:26
    The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Eileen from Kyrgyzstan - 2018.09.29 13:24
    Write your message here and send it to us