Factory wholesale Neisseria Gonorrhoeae Et Chlamydia Trachomatis - Screening Test for Cervical Pre-cancer and Cancer – Liming Bio

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We are also specializing in improving the things management and QC method in order that we could retain terrific edge inside the fiercely-competitive small business for V. Cholerae O1 Or O139 Antigens, Chlamydia Trachomatis Antigen Rapid Test, Coronavirus, We always provide best quality products and excellent service for the majority of business users and traders . Warmly welcome to join us, let's innovate together, and fly dreams.
Factory wholesale Neisseria Gonorrhoeae Et Chlamydia Trachomatis - Screening Test for Cervical Pre-cancer and Cancer – Liming Bio Detail:

Screening Test for Cervical Pre-cancer and Cancer2

INTENDED USE
The StrongStep® HPV 16/18 Antigen Rapid Test Device is a rapid visual immunoassay for the qualitative presumptive detection of HPV 16/18 E6&E7 oncoproteins in female cervical swab specimens. This kit is intended to be used as an aid in the diagnosis of Cervical Pre-cancer and Cancer.

INTRODUCTION
In developing countries, cervical cancer is a leading cause of cancer related death of women, due to the lack of implementation of screening tests for cervical pre-cancer and cancer. A screening test for low resource settings should be simple, rapid, and cost effective. Ideally, such a test would be informative regarding HPV oncogenic activity. Expression of both HPV E6 and E7 oncoproteins is essential for cervical cell transformation to occur. Some research results demonstrated a correlation of E6 &E7 oncoprotein positivity with both severity of cervical histopathology and risk for progression. Hence, E6&E7 oncoprotein promises to be an appropriate biomarker of HPV-mediated oncogenic activity.

PRINCIPLE
The StrongStep® HPV 16/18 Antigen Rapid Test Device has been designed to detect HPV 16/18 E6&E7 Oncoproteins through visual interpretation of color development in the internal strip. The membrane was immobilized with monoclonal anti-HPV 16/18 E6&E7 antibodies on the test region. During the test, the specimen is allowed to react with colored monoclonal anti-HPV 16/18 E6&E7 antibodies colored particals conjugates, which were precoated on the sample pad of the test. The mixture then moves on the membrane by capillary action, and interact with reagents on the membrane. If there were enough HPV 16/18 E6&E7 oncoproteins in specimens, a colored band will form at the test region of the membrane. Presence of this colored band indicates a positive result, while its absence indicates a negative result. Appearance of a colored band at the control region serves as a procedural control. This indicates that proper volume of specimen has been added and membrane wicking has occurred.

SPECIMEN COLLECTION AND STORAGE
■ The quality of specimen obtained is of extreme importance. As much as cervical epithelial cell should be collected by the swab. For cervical specimens:
■ Use only Dacron or Rayon tipped sterile swabs with plastic shafts. It is recommend to use the swab supplied by the kits manufacturer(The swab are not contained in this kit, for the ordering information, please contact the manufacture or local distributor, the cataloge number is 207000). Swabs from other suppliers have not been validated. Swabs with cotton tips or wooden shafts are not recommended.
■ Before specimen collection, remove excess mucus from the endocervical area with a separate swab or cotton ball and discard. Insert the swab into the cervix until only the bottommost fibers are exposed. Firmly rotate the swab for 15-20 seconds in one direction. Pull the swab out carefully!
■ Do not place the swab in any transport device containing medium since transport medium interferes with the assay and viability of the organisms is not required for the assay. Put the swab to the extraction tube, if the test may be run immediately. If immediate testing is not possible, the patient samples should be placed in a dry transport tube for storage or transport. The swabs may be stored for 24 hours at room temperature (15-30°C) or 1 week at 4°C or no more than 6 month at -20°C. All specimens should be allowed to reach a room temperature of 15-30°C before testing.

Screening Test for Cervical Pre-cancer and Cancer3
Screening Test for Cervical Pre-cancer and Cancer4

Cervical Pre-cancer and Cancer 1


Cervical Pre-cancer and Cancer 2


Instructions


Product detail pictures:

Factory wholesale Neisseria Gonorrhoeae Et Chlamydia Trachomatis - Screening Test for Cervical Pre-cancer and Cancer – Liming Bio detail pictures

Factory wholesale Neisseria Gonorrhoeae Et Chlamydia Trachomatis - Screening Test for Cervical Pre-cancer and Cancer – Liming Bio detail pictures


Related Product Guide:

We are going to make every single effort for being excellent and excellent, and accelerate our ways for standing while in the rank of international top-grade and high-tech enterprises for Factory wholesale Neisseria Gonorrhoeae Et Chlamydia Trachomatis - Screening Test for Cervical Pre-cancer and Cancer – Liming Bio , The product will supply to all over the world, such as: Iceland, Bolivia, Mauritania, We always adhere to follow the honesty, mutual benefit, common development, after years of development and the tireless efforts of all staff, now has perfect export system, diversified logistics solutions, comprehensive meet customer shipping, air transport, international express and logistics services. Elaborate one-stop sourcing platform for our customers!
  • The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
    5 Stars By Bella from Germany - 2017.09.16 13:44
    Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Priscilla from Brisbane - 2018.09.23 17:37
    Write your message here and send it to us